video

High Frequency Wide Band Partial Discharge Current Transformer LO-HFCT-150

Partial discharge (PD) monitoring is now an internationally recognized and widely adopted technique for diagnosing the insulation condition of electrical equipment. It is mainly used for routine inspections or on-site testing of high-voltage equipment in substations. By monitoring and analyzing partial discharge signals within Gas Insulated Switchgear (GIS), and utilizing a centralized data analysis system for processing, visualization, and alarm output, it enables effective monitoring and assessment of the operating condition of GIS equipment, thereby preventing unexpected failures of high-voltage systems.

  • Produkteinführung

Wuxi Liou Electronics Co.,Ltd is one of the leading manufacturers and suppliers of high frequency wide band partial discharge current transformer lo-hfct-150 in China. Our factory offer high quality customized products made in China with low price. Welcome to contact us for quotation.

 

 

P/N: LO-HFCT-150

 

 

Partial discharge (PD) monitoring is now an internationally recognized and widely adopted technique for diagnosing the insulation condition of electrical equipment. It is mainly used for routine inspections or on-site testing of high-voltage equipment in substations. By monitoring and analyzing partial discharge signals within Gas Insulated Switchgear (GIS), and utilizing a centralized data analysis system for processing, visualization, and alarm output, it enables effective monitoring and assessment of the operating condition of GIS equipment, thereby preventing unexpected failures of high-voltage systems.

The LO-HFCT series high-frequency partial discharge sensors are widely applicable to PD detection in high-voltage electrical equipment of various voltage levels, including cables, switchgear, GIS, generators, PT cabinets, and circuit breakers. These sensors can be installed on the grounding lines of cable terminations/surge capacitors, cable bodies or shielding layers, as well as on the neutral lines of generators and transformers. They provide reliable real-time online monitoring and diagnosis of discharge activities in high-voltage equipment, enabling digitalized substation maintenance. This ensures a solid foundation for end users to conduct online PD assessment throughout the expected lifecycle of equipment, guaranteeing safe and reliable operation

 

  • Wide frequency band, can work in the range of 100kHz to 100MHz;
  • Waterproof rating can reach IP66, suitable for indoor and outdoor use.

 

  • metal-enclosed switchgear,
  • pole-mounted switches,
  • transformers, and primary high-voltage instrument transformers across various voltage levels.

 

56 copy

 

 

P/N

LO-HFCT-150

F

0.1MHz-100MHz

S

5pC

12mV/mA

50Ω

-40℃-+70℃

-40℃-+85℃

O

BNC-KF-1

P

IP66 After installation, the output connector must be properly protected.

Φ

Φ150mm

 

 

564

 

45

 

Beliebte label: high frequency wide band partial discharge current transformer lo-hfct-150, China, manufacturers, customized, quotation, low price, made in China